Zurn Wilkins 4-375OSY 4" RPZ Backflow Preventer - OSY - Flanged
Sale!

Zurn Wilkins 4-375OSY 4″ RPZ Backflow Preventer – OSY – Flanged

Original price was: $5,806.99.Current price is: $298.98.

SKU: 6137309954223 Category:

Description

Zurn Wilkins 4-375OSY 4″ Reduced Pressure Principle Assembly (RP) Backflow Preventer – OS&Y Gate Valves, Lead-Free, Flange x Flange


Product Overview

The Zurn Wilkins 4-375OSY Reduced Pressure Principle Assembly (RPZ) Backflow Preventer provides high hazard protection for potable water systems. With a flanged ductile iron body, OS&Y gate valves, and lead-free construction, it’s engineered to stop both backsiphonage and backpressure from introducing contaminants into drinking water.

Built with a short lay length for tight installations, a low headloss compound check for improved performance, and a single access cover for easier servicing, the 4-375OSY is a proven choice for commercial and industrial backflow prevention.


Features & Benefits

  • 4″ RPZ Backflow Preventer with OS&Y gate valves for maximum reliability

  • Short lay length simplifies installation in confined spaces

  • Low headloss design improves flow performance in demanding systems

  • Epoxy-coated ductile iron body resists corrosion and extends service life

  • Single access cover allows quick maintenance without full disassembly

  • Flexible connection options with flange x flange ends

  • Lead-free compliant to meet potable water standards


Specifications

  • Size: 4″

  • End Connections: Flanged, ANSI B16.1 Class 125

  • Maximum Working Pressure: 175 PSI

  • Maximum Temperature: 140°F

  • Hydrostatic Test Pressure: 350 PSI

  • Body Material: Ductile Iron, ASTM A 536 with FDA-approved epoxy finish

  • Internals: Stainless steel, NORYL™, EPDM seals, Buna-N O-rings

  • Sensing Line: Stainless steel braided hose

  • Shutoff Valves: OS&Y gate valves (lead-free)

  • Certifications:

    • ASSE® 1013

    • AWWA C511 & C550

    • IAPMO® Listed

    • CSA® Certified

    • UL® Classified / C-UL® Classified

    • FM® Approved

    • USC FCCCHR Approved

    • Meets NSF/ANSI/CAN 61 (≤0.25% weighted average lead content)


Installation Tips

  • Install in accordance with local codes and plumbing standards.

  • Mount assembly 12″–30″ above floor drains with adequate clearance for testing and service.

  • Ensure relief valve discharge is piped to a safe drainage point.

  • Avoid submersion of any part of the assembly.

  • Test the backflow preventer upon installation and perform routine annual testing.


FAQs

Q: What type of protection does the 4-375OSY provide?
A: It protects potable water systems from high hazard backflow conditions, including both backsiphonage and backpressure.

Q: Can this unit be installed in tight spaces?
A: Yes, its short lay length design makes it ideal for confined installation areas.

Q: Are the OS&Y gate valves included?
A: Yes, this model comes with flanged OS&Y shutoff valves.

Q: Is it compliant with lead-free potable water standards?
A: Yes, it meets NSF/ANSI/CAN 61 requirements with ≤0.25% weighted average lead content.

Q: How often should it be tested?
A: Backflow preventers should be tested at installation and at least annually to maintain compliance.

Reviews

There are no reviews yet.

Be the first to review “Zurn Wilkins 4-375OSY 4″ RPZ Backflow Preventer – OSY – Flanged”

Your email address will not be published. Required fields are marked *